REMOTE AUXILIARY AIR CONDITIONING
AND AIR DISTRIBUTION FOR
PETERBILT 379 CHASSIS
INSTALLATION GUIDELINES
for Peterbilt Truck Model 379 with a 70" Sleeper
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - PETERBILT 379 CHASSIS

ENGLISHDometic Environmental CorporationRev. 20080221ID: 2520REMOTE AUXILIARY AIR CONDITIONING AND AIR DISTRIBUTION FORPETERBILT 379 CHASSISINSTALLAT

Page 2 - ENGLISH2

ENGLISH10Peterbilt 379 Installation Guidelines INSTALLING THE SUPPLY AIR DISTRIBUTIONFor this installation, we will install 4" ducts. Depend-ing

Page 3 - CONTENTS

ENGLISH 11Peterbilt 379 Installation GuidelinesFigure 10 - Installing the plenum on the CHEBInstalling the Plenum on the CHEBUsing a 1/4" nut

Page 4

Dometic Environmental CorporationP.O. Box 15299 I Richmond, VA 23227 USA I 804-746-1313 I Fax 804-746-7248 www.dometictruck.com I sales@dometict

Page 5 - CHEB and condensing unit

ENGLISH2COPYRIGHT © 2008 Dometic Environmental Corporation, All Rights Reserved.No part of this publication may be reproduced, translated, stored in a

Page 6 - Control mounted

ENGLISH 3Peterbilt 379 Installation GuidelinesCONTENTSINTRODUCTION 4LOCATING THE COMPONENTS 5INSTALLING THE CONTROL 6 – 8INSTALLING THE RETURN AIR

Page 7

INTRODUCTIONThis document contains supplemental guidelines for installing the Qt-series control and air distribution for the Dometic auxiliary air con

Page 8

ENGLISH 5Peterbilt 379 Installation GuidelinesLOCATING THE COMPONENTSThe Dometic remote auxiliary air conditioning system consists of two basic co

Page 9 - ENGLISH 9

ENGLISHPeterbilt 379 Installation Guidelines 6Figure 3a - Control/Display panel mountedFigure 3b -Alternative Control/Display panel mounting locationC

Page 10 - Figure 9 – Duct combiner

ENGLISH7Peterbilt 379 Installation GuidelinesInstalling the Power Logic BoxThe Power Logic Box (PLB) is commonly mounted on the front wall

Page 11 - IMPORTANT!

ENGLISH8Peterbilt 379 Installation Guidelines ROUTING CABLESThe box contains several types of cables:• Wires enclosed in split loom• Flexible power ca

Page 12 - ID: 2520 Rev. 20080226

ENGLISH 9Peterbilt 379 Installation GuidelinesFigure 6 - Location for cutting return air ventFigure 7 - Return air vent hole cutINSTALLING THE RETURN