Page view 9
10
5.1
5.4
5.3
max.
5.0
5.2
min.
Initial Operation
The device must be plugged into a properly
earthed socket.
The miniBar achieves its operating
temperature after several hours.
INSTRUCTION FOR USE
Temperature Control
The miniBar is fitted with an electronic
temperature control. The thermostat control
button is situated in the internal containers
rear area. (RH 355LD, RH 356LD: the
thermostat button is situated in the
unrefrigerated compartment).
Automatic Defrost Function
The first defrosting phase commences 15 hours after the initial operation
(5.1) and lasts for two hours.
After this, the device operates for 22 hours at a time, followed by a
defrosting period of 2 hours .
The ice layer must never be removed using
force, nor must the defrosting process ever
be accelerated using a heater.
Ice-Making
1.
2.
3.
4.
max.
A
B
S
TT
The miniBar operates silently !
TT
TT
S
Making the ice takes approximately 2-4 hours at an average ambient
temperature of 25°C.
For Figure 3: In all miniBars, the ice tray (A) must be put on the left hand
side of the vaporiser plate (B). An exception is model RH356. In this
model, the ice tray must be placed on the right hand side of the vaporiser
plate.