Dometic RM7655L User Manual Page 27

  • Download
  • Add to my manuals
  • Print
  • Page
    / 30
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
27
D+
connection and Solar Control connection
( RM 7605L only )
D+ connection
The D+ control connection must be connected to the respective vehicle
terminal (alternator signal while motor is running).
Solar control input (S+):
Connection only when using a solar system with a solar charging con-
troller with AES output.
The respective solar charging controllers are available from a specialized
dealer.
The Solar (S+) control connection must be connected to the respective
terminal of the solar charging controller (AES output).
Cable cross-sections
There are no particularly high current flows via the D+ and S+ connection;
therefore no particularly large cross-section is required for these connections
(approx. 1mm²).
Terminal strip DC
connections
(RM 7601 and RM 7605)
Retrofitting
Connections:
A = Ground heating element DC
B = Plus heating element DC
C = Ground electronics
D = Plus electronics
(RM7605)
D+ = alternator signal
S+ = AES-input-control signal
(solar charge regulator)
RETROFITTING
From the manual energy mode to the automatic energy mode
For all RM 7601 appliances (MES) there is an additional possibility for retrofitting
to an RM 7605 device with AES functions.
Please consult your nearest Dometic Customer Service or your specialist dealer.
6.9.3
6.9.4
6.9.5
A
B
D
C
permanent DC-connection
12V DC heating-connection
Page view 26