Dometic EA 355 User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
TECHNOLOGY FOR LIFE
Laboratory / Medicine / Pharmaceutical Refrigerators I +4°C
The Safety Standards developed by Dometic define certain significant technical
features of a product. These ensure the safe storage of the preparations as well
as the trend-setting safety of the user.
The Dometic Gold Safety Standard
efficiently complements the safety
requirements of the Dometic Silver
Safety Standard and therefore exceeds
even the official standards. Gold models
are denominated with a “G”.
SAFETY
STANDARD
GOLD
DOMETIC
The new “green” models (denominated
with a “
G
”) convince by their technical
optimizations in terms of economy and
enviromental protection. Characteristic
features are :
use of natural gases as refrigerants
40-60% less energy consumption
up to 40% less power needed
over 80% less heat ejection
In addition, the new “green” models stand out because
of improved hold over times thanks to optimized door
insulation and drastically reduced noise level for more
workplace convenience.
MODEL
LR 110 G
G
LR 250 G / G
G
LR 410 G / G
G
LR 490 G / G
G
LR 750 G / G
G
DIN 58345 (Refrigerators for drugs)
GMP Clean Room Class A / ISO 5 (ISO EN 14644-1)
Dometic Electronic
Key-operated power switch (power ON/OFF)
Safety door lock
Digital temperature indicator (display: 0.1 digits)
Controlled fan cooling system for constant temperature and even temperature
distribution across the entire refrigerating chamber. Automatic fan switch-off when
front door opens
Self-contained alarm system with integrated battery takes over the alarm function
and temperature value measurements in case of power failure for at least 48 hours
Acoustic/visual alarm signal in case of temperature alarm and power failure
All relevant data of temperature alarm and power failure alarm are stored in the
alarm history. Such as date and time of start and end, min. max and average
temperature
Alarm function test: simulation of a temperature rise or drop in order to test the
alarm functionality
Control via self-diagnostic system
Safety thermostat prevents dropping of the cold storage products’ temperature
below +2°C
LED lighting
Door opening alarm
Remote transmission alarm signal (via potential-free contact) in case of temperature
alarm (change-over contact)
Remote transmission alarm signal (via potential-free contact) in case of power
failure (change-over contact)
Automatic closing of the front door below a door opening angle of 90°
Interior made from stainless steel
Climate class (ambient temperature range) SN/T (+10°C to +43°C)
Smooth castors with stabilizers for optimum flexibility of movement
RS 485 interface for the display of all operating and control functions (hardware
and software settings) via DMN monitoring software on a peripheral device
(computer)
DMN Software package
DCU - Dometic Communication Unit
standard optional – not available
Page view 2
1 2 3 4 5 6 7 8 ... 11 12

Comments to this Manuals

No comments