11.4 Connection of gas supply
Always connect in the following sequence:
GAS BOTTLE PRESSURE-REGULATOR
APPLIANCE.
To connect the pressure regulator to the gas bottle,
the valve of the gas bottle must be closed. Connect
the pressure regulator to the bottle by screwing
firmly. The pressure regulator must be compatible
for propane 11" water gauge. (2.75KPA)
To connect the appliance to the regulator an
approved flexible gas hose must be used, this hose
should be of a minimum length. Connect the gas
hose to the Pressure Regulator by screwing,
ensure this is a gas tight connection.
When fitting the gas hose from the pressure
regulator to the appliance be sure to use two
spanners one to hold the gas connection at the
back of the appliance to avoid straining and
possible damage.(Fig. 10)
The gas bottle (Propane) may only be used in an
upright position and particular care must be taken
every time the appliance is connected to the gas
bottle to ensure that there are no leaks, that the
tubing (rubber hose) is not under tension or kinked,
and that it is not in contact with hot surfaces.
The tubing and the gas bottle should always be
located in positions where they will not be tripped
over or otherwise inadvertently disturbed.
Before attempting to light the burner, every time
after connection, turn on the gas at the bottle and
check the gas connections for leaks by applying a
soap and water solution over them and watching for
bubbles, which would indicate a leak.
After testing dry off traces of detergent.
For your safety:
Do not check for leaks with a naked flame! Do not smoke while checking for leaks!
Dichtung
B
Figure 10.
seal
12. Environmental protection
information
The appliance does not contain any CFCs/HCFCs.
Ammonia (natural hydrogen and nitrogen compound)
is used as refrigerant agent in the cooling unit.
The ozone-friendly cyclopentane is used as a blowing
agent for the PU foam insulation.
Sodium chromate is used for corrosion protection
(less than 2 weight % of the coolant).
13. Recycling
After unpacking the appliance, the packing materials
should be delivered to a local collection site. At the
end of its useful lifetime, the appliance should be
delivered to a specialised recycling firm, which
reclaims the usable materials. The rest is properly
destroyed.
This appliance complies with the following EEC
directives:
LVD-Directive 73/23/EEC with amendment
90/683/EEC
EMC-Directive 89/336/EEC
Gas-Directive 90/396/EEC