Check List
10
5.4
Failure : No cooling (the aggregate at the back of the device is cold).
Possible Cause Self Help Authorised Service
a.) The thermostat is set to “0”.
b.) The device plug is not
plugged in.
c.) No voltage in socket.
a.) Set temperature control to
middle position.
b.) Plug in device plug.
c.) Check building fuse..
Failure : No cooling (the aggregate is warm).
Possible Cause Self Help Authorised Service
a.) The device was only
switched on a short while ago.
b.) Defective cooling aggregate.
a.) Switch on the device and
let it run for 1 hour.
b.) Exchange fridge
Failure : Poor Cooling Performance.
Possible Cause Self Help Authorised Service
a.) The cooling aggregate is not
sufficiently ventilated.
b.) The fridge door does not
close tightly.
c.) Light permanently on when
door closed.
d.) The fridge was stocked a
short while ago.
a.) Check that the ventilation
grilles are not covered. Check
that device has been installed
properly (installation instruction
4.5)
b.) Check installation in line
4.5.
d.) Check fridge after 1 hour
for proper cooling.
b.) Is door magnet
there? Install new door,
if required.
c.) Replace lighting
sensor. Install new door,
if required.
Failure : Frost formation in fridge.
Possible Cause Self Help Authorised Service
a.) The fridge door does not
close tightly.
a)Check installation in line 4.5.
a.) Is door magnet
there? Install new door,
if required.
Page view 9