Page view 12
Water supply
Electrical installation
ELECTRICAL INSTALLATION MUST BE CARRIED OUT BY QUALIFIED
PERSONNEL ONLY !
The 12V DC connection to the toilet electro-
nics is shown in the adjacent figure.
Connect by right polaraity :
RED
+ WHITE
-
The connection cable must have a cross-
section of at least 4 mm². It must be protec-
ted by an 8-amp-fuse (wiring diagram pg.15)
The board battery should be protected by an
undervoltage cut-out.
Connection display on the control electronics
6.6
The water supply is provided with
the aid of a pump (this can also be
the pump available in the vehicle)
and a hose connection from the
fresh-water container.
Fasten a hose clamp to the water-supply connection.
6.7
6.7.1
13
display panel
4-strand, coded connection cable
electronic board
The 4-strand, coded connection cable (A)
(cable cross-section 1 mm²) is connected to
the circuit board as shown in the figures.
A
A
base station
red
(+12V)
white
(GND)
12V-- connection
+
-
Page view 12