INSTALLATION ANDOPERATING INSTRUCTIONSREFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION.Contents:PageInstallation 4Operating Instructions 8Maintenance &a
DESCRIPTION OF OPERATINGMODESAUTO MODEWhen operating in the AUTO mode, the AUTO modeindicator lamp (A) will illuminate. The control system willautomat
HOW TO USE THE REFRIGERATORFOOD STORAGE COMPARTMENTThe food storage compartment is completely closed andunventilated, which is necessary to maintain t
GAS EQUIPMENT ASSEMBLYELECTRIC EQUIPMENTCARTRIDGE HEATERThe heat necessary for the operation of an absorptioncooling unit is supplied by an electric h
B. Check all connections in the LP gas system (at theback of the refrigerator) for gas leaks. The LP gassupply must be turned on. Apply a non-corrosiv
H. LP gas pressure low at burner.Set main regulator so pressure does not drop below11 inches water column at pressure tap.I. Burner not located proper
21345111113CERTIFIED VENT SYSTEM KITSRefr. KitModel No. Components DrawingNDR 1062 4A Roof Vent 3103633 Base3103634 Cap(Both Required)Lower Side Vent
Positioning of shelvesPut a screwdriver into the slot of the shelf lock.Turn the screwdriver counterclockwise.Remove the shelf locks from the wire she
MO-FO 0111
HeaterBurner jetD12A2 - WAY display panel.FIG. 2GECB3FLEGEND 2-WAY AMES Model 1. Main Power Button ON/OFF2. AUTO/GAS Mode Selector Button3. Temperatur
INSTALLATIONGENERAL INSTRUCTIONThis appliance is designed for storage of foodsand storage of frozen foods and making ice.The refrigerators outlined he
is required to maintain the automatic energy system).The DC lead connections are at terminals located at therear of the refrigerator. (see FIG. 1). On
2. Once the lower front strip is slipped under the hinge,the part is possible to swing into place as shown inFIG. 6.3. Secure the refrigerator and the
CERTIFIED INSTALLATIONCertified installations require one roof vent and onelower side vent.For "Certified Vent System Kits" see page 15.For
Overall Recess Refrigerator Dimensions Dimensions ModelHeight Width Depth Height Width DepthABCHWDinch 60-51/64 24-7/8 26-5/8 59-15/16 23-11/
START UP INSTRUCTIONSA. A continuous 12 volt DC supply must be available forthe electronic control to function.B. Press the main power ON/OFF button (
Comments to this Manuals