FOR YOUR SAFETY
If you smell gas:
1. Open windows and door.
2. Don’t touch electrical switches.
3. Extinguish any open fl ame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
ammable vapors and liquids in the
vicinity of this or any other appliance.
WARNING
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional infor-
mation consult a qualifi ed installer, serv-
ice agency or the gas
supplier.
RA/RM-1D
RA/RM-2D
REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION
INSTALLATION AND
OPERATING INSTRUCTIONS
RM 4605
RM 2455
RM 2555
RM 2355
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - OPERATING INSTRUCTIONS

AES III825 12 40-02FOR YOUR SAFETYIf you smell gas:1. Open windows and door.2. Don’t touch electrical switches.3. Extinguish any open fl ame.4. Immedia

Page 2

10Electrical connection pointGas connection pointElectrical connection pointGas connection pointpressure testpointFlue outletRM 2555Electrical connect

Page 3 - CONTENTS

11SECURING THE REFRIGERATORFor the best cooling performance, when installing the refrigera-tor model(s): RM 2355 - the installer must block the space

Page 4

12Once the lower front strip is slipped under the hinge, the part is possible to swing into place as shown in Fig. 13.Secure the refrigerator and the

Page 5 - DEFROSTING

13CROSS-SECTIONSThe D+ (alternator) is a signal cable and therefore 1-1.5 mm2is suffi cient. Connection to 12V + and - must be done with a 10 mm2 wire

Page 6 - TROUBLESHOOTING

14With screws (see Fig. 20 and Fig. 22)To mount the door panel, follow these steps: Open the door 90 degrees.On new refrigerators, the decoration str

Page 7 - INSTALLATION INSTRUCTIONS

155123

Page 8 - CLEARANCES

16RM 2355RM 2455RM 2555RM 4605Overall dimensions Height (mm)76694811041385Width (mm)556632632632Depth incl. cooling unit (mm)577627627627Recess dimens

Page 9 - CONNECTING POINTS

17REARVIEW EQUIPMENTD+Power modulecover (PC board)ReigniterRelayFlexible cordInlet fittingTerminal block12V DC onlyD+12 or 24V DCDrain water hoseBurne

Page 10

18WIRING DIAGRAMRM 2355 - RM 2455 - RM 2555RM 4605

Page 11 - INSTALLATION/BUILDING-IN

19ThermostatSparkGas valveFlame detector deviceLock out indicationTW TS TS TWI TS TWI TSWORKING INSTRUCTIONS FOR THE GAS SAFETY SYSTEM WORKING DIAGRAM

Page 13 - MOUNTING INSTRUCTIONS

20Use the Airing Position Card tokeep the doors ajar if the refrigeratorwill not be in use for an extendedperiod of time or put in storage.1234APPENDI

Page 14

21APPENDIX A - AIRING POSITION CARDRM 460512543

Page 18 - WIRING DIAGRAM

3INTRODUCTIONWe are pleased that you have chosen this refrigerator and hope you will derive much satisfaction from using it. The refrigerator is desig

Page 19 - TECHNICAL SPECIFICATIONS

4LP GAS OPERATIONAES will select LP gas operation under the following conditions:No AC (230-240V) availableEngine not running (no high current at 12V

Page 20 - RM 2455 AND RM 2555

5SWITCHING BETWEEN ENERGY SOURCESWhen switching from one energy source to another, there are some delays implemented in the AES system. The 15 min. de

Page 21

6CLEANING THE REFRIGERATORClean the inside of the refrigerator regularly to keep it fresh and hygienic.Soak a cloth in a solution consisting of a teas

Page 22

7REMOVAL OF FLUE GASESThe ventilation passage at the rear of the recess, between the outer wall of the vehicle and the refrigerator must be sealed off

Page 23

8CLEARANCESMinimum clearances (mm) to combustible materials are:RM 2355(Fig. 5 & Fig. 6)RM 2455 - RM 2555 - RM 4605(Fig. 5 & Fig. 7)GTop00KSid

Page 24 - MO-M 0552

9CONNECTING POINTSDimensions to connecting points (mm).Electrical connection pointGas connection pointGas pressure testpointFlue outletGas connection