9. Reversing the door hang, (Fig. 6)
Lay the appliance on its back. Remove the 8
screws (1). Remove the door, together with the two
hinges (2), from the housing.
Remove the two cover caps (3) from the housing and
place them in the open hinge holes in the housing.
Place the bottom righthand hinge in the top left of the
door and the top righthand hinge in the bottom left of
the door and hang the door on its hinges in the open
cover cap holes in the housing. Secure the hinges
and cover caps with the 8 screws.
Check that the door closes easily and is sealed
properly.
Figure 6.
10. Replacing the decorative
door panel, (Fig. 7-9)
Remove the two screws (1) from the upper hinge of
the door.
Pull the door together with the hinge away from the
housing and up off the lower hinge bolt (2-3).
Figure 7.
Remove screws (4) and pull off the frame edge (5).
Slide the decorative panel (6) out of the door frame
and insert the new panel (7), so that the upper
edge of the panel runs exactly parallel to the upper
edge of the frame. A new panel can be inserted
more easily into the upper edge of the frame when
the two corners are cut off by approx. 5 x 5 mm (8).
Put the frame edge (5) back in place and secure
with screws.
Figure 8.
6
warmer temperature. The effect of any adjustment can
be checked by means of the thermometer after
leaving the refrigerator operating for a further period to
settle down again.
Figure 4.
6. Useful suggestion
Do not overfill the appliance. Put warm foods and drinks
in the appliance only when they have cooled down to
room temperature. It is advisable to leave some space
between the products in the cabinet to ensure efficient
and even cooling. If the shelves are packed too tightly
there may be unacceptable temperature variations.
7. Defrosting, cleaning and
maintenance
Frost will gradually form on the cooling surfaces and it
must not be allowed to become too thick since it acts
as an insulator and interferes with the cooling.
This frost-formation is kept back by the FUZZY LOGIC
system built into the appliance by switching off the unit
for two hours in every 24 hours. The frost will melt and
the defrost water will run through the drain tube from
the drip channel into an evaporating vessel located at
the bottom rear of the refrigerator (Fig 5.). The defrost
water will evaporate automatically into the circulating
air and the vessel will not need emptying manually.
To switch off the unit, turn the thermostat knob to "0",
disconnect the refrigerator from the electricity supply
and leave the cabinet door open. After defrosting the
cabinet interior should be wiped out with a clean,
damp cloth.
Figure 5.
8. Changing the lightbulb (If available)
If the lightbulb needs changing, pull out the plug and
proceed as follows:
Press the metal reflector to one side and draw the
lamp covering backwards. Replace the bulb and push
the covering back into place.
A new 10-watt bulb can be obtained at any service
shop.