CERTIFIED INSTALLATION
Certified installations require one roof vent and one
lower side vent.
For "
Certified Vent System Kits
" see page 15.
For further information contact your dealer or distributor.
METHODS OF INSTALLATION
The method of installation is shown in FIG. 9. It is
essential that all maximum or minimum dimensions are
strictly maintained as the performance of the refrigerator
is dependent on adequate flow of air over the rear of the
refrigerator.
NOTE: The upper vent should be centered over
the condenser coil at the back of the refrigerator.
VENTILATION HEIGHTS
Installation with roof Minimum ventilation
vent and lower side vent heights in
Refrigerator Inches mm
NDR 1292 65 1651
CLEARANCES
Minimum clearances in inches to combustible materials
are:
G: Top 0
K: Side 0
L: Bottom 0
M: Rear 0
N: See NOTE: Clearance "N" below.
NOTE: Clearance "M" is between the rearmost part of
the refrigerator and the wall behind the refrigerator.
NOTE: Clearance "N" is the distance between the bot-
tom of the lower vent to the roof material. For ventilation
height, see table VENTILATION HEIGHTS
See Figures 9, and 10.
Condenser
Ventilation
height
FIG. 9
13-5/8"
28-5/8"
LOWER VENT CUTOUT
FIG. 10
N
M
G
KK
L
NOTE: Wood Strip
MUST be in place.
7