INSTALLATION AND OPERATING INSTRUCTIONS
E. Install ceiling template by sliding lower duct over upper
duct.
F. Start each mounting bolt by hand before tightening any
of them. The four (4) threaded inserts in the base pan can
be seen to aid in starting the bolts.
G. Use a battery drill and run all 4 bolts up until they touch
the template but are not tight.
H. With the ceiling template flat against the ceiling install
the 6 wood screws at an angle, so as to stretch and
flatten the template. Three across the front and 3 across
the back of the template. See FIG.. 11.
WIRING OF SYSTEM
Note: All wiring must comply with the National Electrical
Code and any Region or Local Codes or regulations.
(Steps A. - F refer to FIG. 13- FIG.14.)
WARNING
!
Disconnect 220-240 volt AC. Failure to fol-
low these instructions could create a shock
hazard causing death or severe personal
injury.
FIG. 11
Wood
Screws
Knobs
I. EVENLY TIGHTEN THE 4 MOUNTING BOLTS TO A
TORQUE OF 4.5 to 5.7 Nm.
This will compress the roof gasket to approximately
10 mm. The bolts are self locking so over tightening is
not necessary. See FIG. 12.
If bolts are left loose there may not be an
adequate roof seal or if overtightened, dam-
age may occur to the air conditioner base or
ceiling template. Tighten to torque specifi-
cations listed in this manual.
CAUTION
FIG. 12
Evenly Tighten
The 4 Mounting
Bolts To 4.5 - 5.7
Nm
WARNING
!
This product is equipped with a 3-wire
(grounded) system for protection against
shock hazard. Make sure that the appliance
is wired into a properly grounded AC circuit
and the polarity is correct. Failure to do so
could result in death, personal injury or dam-
age to the equipment.
A. Route supply line into junction box through provided
Connector. 150mm leads are sufficient for connection
to unit wires and ground screws.
B. Connect RED wire in junction box to RED wire from
supply line.
C. Connect BLACK wire in junction box to BLACK wire
from supply line.
D. Connect supply ground wire to identified ground screw
in junction box.