INSTALLATION GUIDE
On installation of the appliance, the technical and administrative regulations of the
country in which the vehicle will first be used must be adhered to. Otherwise the
refrigerator must be installed as described in these instructions.
In Europe, for example, gas appliances, cable laying, installation of gas
cylinders, as well as approval and checking for leaks must comply with
EN 1949 for liquid gas units in vehicles.
Installation
The appliance and its fume extraction shall be installed in such a way as to be acces-
sible for servicing at all times and must be capable of easy removal and installation.
The appliance may only be installed by authorised personnel.
Installation and connection of the appliance must comply with the latest
technical regulations, as follows:
The electrical installation must comply with national regulations.
Technical regulations EN 60335-1, EN 60335-2-24, EN 1648-1 , EN 1648-2
The gas installation must comply with national regulations.
Technical regulations EN 1949
Technical regulations EN 732
Local and building control department requirements
The appliance shall be installed in such a way that it is shielded from
excessive heat radiation.
Excessive heat impairs performance and raises the energy consumption of the
refrigerator.
Side installation
If the appliance is installed on the same side of the vehicle as the entrance
door, it is desirable that the door does not cover the refrigerator’s vents. If this cannot
be avoided there must be a gap of at least 25mm between the door and the vents.
(Fig.1, distance between door and wall min. 25 mm)
Awnings are often placed at the door side of a caravan. In this case the ventilation
grilles must be kept open and the awning area must be well ventilated.
Otherwise the cooling performance could be impaired in high ambient temperatures.
88..00
8.1
Fig.1
Air vent grille not
blocked: OK!
8.1.1
Air vent grille blocked
Gap between door and vent
grille - min. 25mm.
Any installation that is not carried out by qualified persons will jeo-