ELECTRICAL CONNECTION
120 V AC CONNECTION
The refrigerator is equipped with a three-prong (grounding)
plug for your protection against shock hazards and should be
plugged directly into a properly grounded three prong recep-
tacle. Do not cut or remove the grounding prong from this
plug!
The free length of the cord is 3 feet. It is recommended that the
receptacle is located to the right side of the refrigerator (viewed
from the rear).
The receptacle should be 3” (from the
bottom of the plastic receptacle) above
the refrigerator mounting floor. This
allows easy access through the vent
door. The cord should be routed to
avoid direct contact with components
that could damage the cord insulation.
12 V DC AND ALTERNATOR (D+) CONNECTION
D+ connection is only valid for models with the
automatic door locking system.
The refrigerator requires a continuous 12 V DC supply to
maintain operation. The DC supply connection is made to the
positive (+) and negative (-) terminals of the terminal block on
the back of the refrigerator.
Correct polarity must be observed when connecting to the DC
supply. Do not use the chassis or vehicle frame as one of the
conductors. Connect two wires at the refrigerator and route to
the DC supply.
It is important that the wires to the 12 V DC terminal is
of proper wire size. The following table displays the recom-
mended size and length of the conductor wires.
MAXIMUM TOTAL CONDUCTOR WIRE LENGTH
Wire length AWG
17 ft
5 m
14
27 ft
8 m
12
For models equipped with the automatic door lock:
The refrigerator requires the connection of a signal wire from
the alternator (D+) in order to maintain the automatic door
travel latch and the temporary gas lockout function.
The vehicle’s alternator (D+) is connected to D+ on the
terminal block.
CONNECTIONS
Battery
B+
Alternator signal wire to the refrigerator
D+
ALTERNATOR
Ignition switch
Charge light
D+ (Alternator signal wire)
Valid for refrigerator mod-
els with the automatic door
locking system.
3”
General view.
Features may vary