FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Don’t touch electrical switches.
3. Extinguish any open ame.
4. Immediately call your gas supplier.
POUR VOTRE SÉCURITÉ
Si vous sentez une odeur de gaz:
1. Ouvrez les fenêtres.
2. Ne touchez à aucun interrupteur.
3. Éteignez toute amme nue.
4. Avertissez immédiatement votre
fournisseur de gaz.
FOR YOUR SAFETY
Do not store or use gasoline or other
ammable vapors and liquids in the
vicinity of this or any other appliance.
POUR VOTRE SÉCURITÉ
Ne pas entreposer ni utiliser de l’essence
ni d’autres vapeurs ou liquides inamma-
bles à proximité de cet appareil ou de tout
autre appareil.
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional infor-
mation consult a qualied installer, serv-
ice agency or the gas supplier.
Une installation, un réglage, une modi-
cation, une réparation ou un entretien non
conforme aux normes peut entraîner des
blessures ou des dommages matériels.
Lisez attentivement le mode d’emploi
fourni avec l’appareil. Pour obtenir de
l’aide ou des renseignements supplémen-
taires, consultez un installateur ou un
service d’entretien qualié ou le fournis-
seur de gaz.
AVERTISSEMENT
!
WARNING
!
iNstallatioN
&
opeRatiNg
iNstRuctioNs
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - AVERTISSEMENT

825129300(French 825129350)©2006-2008 Dometic, LLCLaGrange, IN 46761DM2862DM3862NDM1062NDR1292RM2351RM2354RM2451RM2454RM2551MO-M 0819 USA Corpora

Page 2

- 10 -Put back the cover. 9. Press the ON/OFF button off and then back on. Nor-10. mal operation of the burner should return. 

Page 3

- 11 -To mount the panel, follow these steps: Open the door 90 degrees. 1. On new refrigerators, the decoration strip is taped 2. inside t

Page 4 - Ventilation requirements

- 12 -To mount the panel, follow these steps: Open the door 90 degrees. 1. On new refrigerators, the decoration strip are 2. taped inside the

Page 5

- 13 -absoRptioN cooliNg systeM

Page 6

- 14 -RM2354, RM2454, RM2554 & DM2663When operating in DC mode (3-way models only), the DC mode indicator lamp is illuminated and all othe

Page 7 - 

- 15 -refrigerator oVerViewCHECKGASAUTOONOFFAUTOMATIC REFRIGERATOR TEMPERATURE CONTROL1 2A B button (main power) mode selector b

Page 8

- 16 -DBONOFFACGASCHECKAESAUTOCOLD12345COLDEST CLCLACA C GE F1 2 3 4 5 button (main power)  mode selector button

Page 9 - 

- 17 -Before starting the refrigerator: Check that all the manual gas valves are in the ON position. Make sure that a continuous 12V DC supply is av

Page 10 - 

- 18 -MoDel total RefRigeRateD (cu.ft)RM2351& RM2354 3RM2451& RM2454 4RM2551 & RM2554 5DM2652, DM2662 & DM2

Page 11 - 

- 19 -5Slide the shelf into the holes on the right-hand side.Put a screwdriver into the slot of the shelf lock. Turn the screwdriver counter clockwise

Page 13 - 

- 20 -cleaNiNgusually done after it is defrosted or put into storage. Use luke-warm w

Page 14 - 

- 21 -DM2652, DM2662, DM2663, DM2852 & DM286212543Use the  to keep the doors ajar if the refrigerator will not be in use for a

Page 15 - DM2662, DM2862 & NDM1062

- 22 -maintenance & serViceTo keep the refrigerator working properly, a qualified service technician should, at least once a year, inspect the conn

Page 16 - DM3862, NDM1062 & NDR1292

- 23 -peRioDic MaiNteNaNce Check the control system by connecting/disconnecting the 

Page 17

- 24 -Symptom Check/Remedial actionThe refrigerator has stopped cooling.Immediately turn the refrigerator off and see a Dometic dealer.Refrigerator

Page 18 - & DM3862 8

- 25 -The following table displays commonly used parts which should be available from your Dometic Service Center. MoDel

Page 19

- 26 - MoDel spaRe paRtsDM2662 DM2663 DM2852 DM2862 DM3862 NDM1062 NDR1292Airing position card3850781-01 3850781-0

Page 20

- 27 - Please visit the website for information and news about Dometic products. You can obtain information about how

Page 21

- 28 -iMpoRtaNt!&best buil

Page 22 - CAUTION

- 29 -THE SELLER NAMED BELOW MAKES THE FOLLOWING WARRANTY WITHRESPECT TO THE DOMETIC PRODUCT:

Page 23 - SLOTSOFTHEBURNER

- 3 -operating instructions ____________ 13refrigerator overview ...13instructions for use . . . . . . . . . . . . . . . . . . . .

Page 24 - Symptom Check/Remedial action

- 30 -RefRigeRatoR owNeR MaiNteNaNce yeaRly RecoRD#USTOMER .AME -ODEL .O $ATEOF0URCHASE!DDRESS 3ERIAL.O3TATE#ITY :IP#ODE0HONE&)234

Page 25 - spaRe paRts

- 31 -RM2351RM2354Power modulecoverFlexible cord12 V DCTerminal blockInlet fittingManual gas shutoff valveBurner jetScrew for protection coverProtecti

Page 26

- 32 -12V DCRelay,3-Way onlyPower modulecoverFlexible cord12 volt DCTerminal blockDrain water hoseInlet fittingManual gasshutoff valveBurner jetScrew

Page 27

- 33 -NDR129212V DCHeatersPower module coverFlue baffleProtectioncoverThermofuseBurner jetManual gasshutoff valveInlet fitting12 voltTerminal blockFle

Page 28 - 

- 34 -RM2351, RM2451 & RM2551RM2354, RM2454 & RM2554appendix e - wiring diagrams

Page 29 - DoMetic RefRigeRatoRs

- 35 -DM2652, DM2852 & DM2862  DM2652, DM2662, DM2852 & DM2862 385 13 9812V D CJABCDEFGCIRCUIT BOARD DISPL

Page 30 - !#45!, 30%#2!.'%

- 36 -DM26631 2 V D CABCDEFGCIRCUIT BOARD DISPLAYFUSE 5ASWITCH LAMPLKHEATER 12V DCLAMPMNRETAINERPSWITCHSOLENOID VALVETHERMISTORCIRCUIT BOARD POWERTH

Page 31

- 37 -NDM1062 NDM1062 U312V D CHABCDEFGCIRCUIT BOARD DISPLAYFUS

Page 32

- 38 -NDR1292 NDR1292 385 13 30U12V D CHABCDEFGCIRCUIT BOARD DIS

Page 33

Dometic Processing Center2320 Industrial ParkwayElkhart, IN 46516FIRST REQUIRED

Page 34 - RM2354, RM2454 & RM2554

- 4 -geNeRal iNfoRMatioNVentilation is one of the requirements for proper cooling unit operation. The installation should be made in such a manner as

Page 35 - DM2652, DM2852 & DM2862

W ARRANTY VERIFICATIONYour prompt registration records your right to protection under the terms and conditions of your warranty.OWNER CONFIRMATION

Page 36 - 385 14 03

- 5 -cleaRaNces Minimum clearances (in inches) to combustible materials: Top (G) 0Side (K) 0Bottom (L) 0Rear (M1) 0 / 1 () 1 T

Page 37 - NDM1062

- 6 -    Width B Depth C Height H Width W Depth DRM2351RM2354inches

Page 38 - NDR1292

- 7 -Be careful when installing the refrigerator models NDM1062 & NDR1292. These are equipped with the latest vacuum i

Page 39 - REQUIRED

- 8 -3. NDR1292Install the screws in the following order: 

Page 40 - ■ ARRANTY VERIFICATION

- 9 -Hole for drain water hoseHoseBoilercasingcoNNectioNsHook up to the gas supply line is accomplished at the manual 

Comments to this Manuals

No comments