Wiring diagrams
1. Wiring diagram with manual ignition and no interior light.
2. Wiring diagram with manual ignition and interior light
battery connection
12V/24V --
mains connection ~
heating-
element
DC-
resistor (replaced by a bridge
for 24V battery voltage)
thermo cut-off current
light DC --
reed contacts
(sensor switching)
to casing
to
ca
sin
g
heating-
element
AC
~
Battery connection 12V/24V -
A = Ground heating element DC, white
B = heating element DC-, red
C = Ground interior light, black
D = Interior light, violet
battery connection DC
mains connection AC
heating-
element
DC
thermo cut-off current
heating-
element
AC
6.9.3