Dometic RM2852 User Manual Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
8
OPERATING
INSTRUCTIONS
IMPORTANCE OF LEVELING A
REFRIGERATOR
In an absorption refrigerator system, ammonia is lique-
fied in the finned condenser coil at the top rear of the
refrigerator. The liquid ammonia then flows into the
evaporator (inside the freezer section) and is exposed
to a circulating flow of hydrogen gas, which causes the
ammonia to evaporate, creating a cold condition in the
freezer.
When starting this refrigerator for the very first time, the
cooling cycle may require up to four hours of running
time before the cooling unit is fully operational.
The tubing in the evaporator section is specifically sloped
to provide a continuous movement of liquid ammonia,
flowing downward by gravity through this section. If the
refrigerator is operated when it is not level and the ve-
hicle is not moving, liquid ammonia will accumulate in
sections of the evaporator tubing. This will slow the cir-
culation of hydrogen and ammonia gas, or in severe
cases, completely block it, resulting in a loss of cooling.
Any time the vehicle is parked for several hours with the
refrigerator operating, the vehicle should be leveled to
prevent this loss of cooling.
The vehicle needs to be leveled only so it is comfortable
to live in (no noticeable sloping of floor or walls).
When the vehicle is moving, the leveling is not critical,
as the rolling and pitching movement of the vehicle will
pass to either side of level, keeping the liquid ammonia
from accumulating in the evaporator tubing.
OPERATION
Before starting the refrigerator, check that all the manual
gas valves are in the ON position. DO NOT forget the
manual shutoff valve on the rear of the refrigerator see
FIG. 1.
This refrigerator is equipped with a control system, which
can be set to automatically select either 120 volt AC or
LP gas operation (AUTO mode), or if desired LP gas
only (GAS mode).
In both AUTO mode and GAS mode operation, the tem-
perature is controlled by a factory preset temperature
setting.
The refrigerator controls will work down to 9.6 volt DC.
Most LP gas appliances used in recreational ve-
hicles are vented to the outside of the vehicle.
When parked close to a gasoline pump, it is pos-
sible that the gasoline fumes could enter this
type of appliance and ignite from the burner
flame, CAUSING A FIRE OR AN EXPLOSION.
FOR YOUR SAFETY, when refueling, shut off all
LP gas appliances which are vented to the out-
side.
! WARNING
Side view View from above
FIG. 11
D
HW
D
C
B
A
Overall Recess
Refrigerator Dimensions Dimensions
Model
Height Width Depth Height Width Depth
ABCHWD
inch 54-21/32 24-7/8 26-1/32 53-3/4 23-11/16 24
RM 2652
mm 1388 632 661 1365 602 610
inch 60-51/64 24-7/8 26-1/32 59-15/16 23-11/16 24
RM 2852
mm 1544 632 661 1522 602 610
This method of installation and these clearances will give you adequate space for service and proper installation.
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 19 20

Comments to this Manuals

Mike M. 05 Dec 2024 | 20:28:39

Where is the AC fuse located at? Thank you.