13. Customer service
Before you call a service engineer, carry out the
following simple tests:
If after checking all the above points, the refrigerator is
still not working satisfactorily, contact your nearest
service engineer. State the problem, model, product-
and serial-number.
(Details of the model, product- and serialnumber are
to be found on the data label in the top left of the
inside compartment.)
In the event of a fault developing, contact your nearest
Service Centre-see local telephone directory.
14. Putting into operation
Technical data:
14.1. Connecting to electrical mains
The appliance may only be operated from
nominal voltage mains as shown on the data
plate. The appliance mains plug may be connected to
a mains socket earthed in accordance with
regulations.
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
The manufacturer declines any liability should
these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance
rating plate.
Problem
The appliance does not
cool sufficiently.
The appliance does not
cool at all.
Possible cause
Thermostat control is set too low.
Too much food to be cooled was
put in.
Door is not shut properly.
Refrigerator not level.
Internal air circulation is restricted.
External air circulation is restricted.
CUC system stopped the
operation.
Plug is not connected to the mains
socket properly.
There is no voltage in the mains
socket.
Solution
Set to a higher position.
Put in less food to be be cooled.
Check if the door is shut.
Level refrigerator.
Provide inside cool air circulation.
Provide outside air circulation.
See operating instruction 5. 2.
Check if the connection is proper.
Check if there is voltage.
(eg. Connect a lamp to the socket).
Model RH 131 RH 141
Type MF20-60 MF20-60
Gross volume 31 litre 41 litre
Mains operation 220V 220V
Input 90W 90W
Energy consumption 0.9 kWh/24h 0,98 kWh/24h
Climate class N N
Refrigerant 159g H
2
O+86g NH
3
159g H
2
O+86g NH
3
8