The wire coloured brown must be connected to the
terminal marked „L“ or coloured red.
Upon completion there must be no cut, or stray
strands of wire present and the cord clamp must be
secure over the outer sheath.
14. Environmental
protection information
The appliance does not contain any CFCs/HCFCs.
Ammonia (natural hydrogen and nitrogen compound) is
used as a refrigerating agent in the refrigeration unit.
The ozone-friendly cyclopentane is activated as a motive
agent for the PU foam insulation.
Sodium chromate is used for corrosion protection (less
than 2 weight % of the coolant).
15. Recycling
After unpacking the appliance, the packing materials
should be delivered to a local collection site. At the end
of its useful lifetime, the appliance should be delivered to
a specialized collection and reprocessing firm, which
reclaims the usable materials. The rest is properly
destroyed.
Appliances bearing this symbol must be
deposited at the designated local reception
point for the disposal of electrical and
electronic equipment.
It is not permitted that this product be
disposed of by way of the normal household
refuse collection system.
Dometic refrigerators bear this symbol on the
specifications plate (data plate) to be found in the interior
of the unit.
This appliance complies with the following EEC
directives:
LVD-Directive 73/23/EEC with amendment
90/683/EEC
EMC-Directive 89/336/EEC
RoHS-Directive 2002/95/EC
13. Putting into operation
Technical data:
13.1. Connecting to electrical mains
The appliance may only be operated from nominal
voltage mains as shown on the data plate. The
appliance mains plug may be connected to a mains socket
earthed in accordance with regulations.
Any electrical work required to install this appliance should
be carried out by a qualified electrician or competent
person.
The manufacturer declines any liability should these
safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance rating
plate.
Only for UK:
The appliance is supplied with a 3 amp plug fitted. In
the event of having to change the fuse in the plug
supplied, a 3 amp ASTA approved (BS 1362) fuse
must be used. Should the plug need to be replaced
for any reason, the wires in the mains lead are
coloured in accordance with the following code:
Green and Yellow: Earth
Blue: Neutral
Brown: Live
The wire coloured green and yellow must be
connected to the terminal marked with the letter „E“ or
by the earth symbol or coloured green and yellow.
The wire coloured blue must be connected to the
terminal „N“ or coloured black.
Model RH 161
Type MF20-60
Gross volume 60 liter
Mains operation 220-240V (AC)
Input 115W
Energy consumption 1.4 kWh/24h
Climate class N
Refrigerant 357g H
2
O+168g NH
3