This appliance is certied under the latest edition of ANSI Z21.19•CSA 1.4 Refrigerators using gas fuel. The installation must
conform with local codes, or in absence of local codes, the following standards as applicable.
CERTIFICATION AND CODE REQUIREMENTS
In the U.S. the installation must conform with:
National Fuel Gas Code, ANSI Z223.1/NFPA 54 (latest edi-
tion).
Recreational Vehicles Code, ANSI A119.2 (latest edition)
Manufactured Home Construction and Safety Standard, Title
24 CFR, Part 3280.
If an external electrical source is utilized, the refrigerator, when
installed, must be electrically grounded in accordance with lo-
cal codes or, in the absence of local codes, the National Electri-
cal Code, ANSI/NFPA 70 - (latest edition).
•
•
•
In CANADA, the installation must conform with:
Natural Gas and Propane Installation Code, CSA B149.1
CSA Z240 RV Series, Recreational Vehicles.
Current CSA Z240.4, Gas-equipped Recreational Vehicles
and Mobile Housing.
If an external electrical source is utilized, the refrigerator,
when installed, must be electrically grounded in accordance
with local codes or, in the absence of local codes, the Canadian
Electrical Code, CSA C22.1, Parts I and II - (latest edition).
•
•
•
VENTILATION HEIGHTS
Minimum ventilation heights
Installation with roof vent and lower side vent
RM2410 34 inches 864 mm
RM2510 42 inches 1067 mm
Minimum
ventilation
height
Condenser
The upper vent should be centered
over the condenser coil at the back of
the refrigerator.
INSTALLATION INSTRUCTIONS
VENTILATION REQUIREMENTS
Ventilation is one of the requirements for proper cooling unit
operation. The installation should be made in such a manner as
to separate the combustion system from the living space of the
mobile home or recreational vehicle. Openings for air supply
or for venting of combustion products should have a minimum
dimension of not less than 1/4 inch.
Proper installation requires one lower fresh air intake and one
upper exhaust vent. Certied installations require one roof vent
and one lower side vent. The ventilation kits shown in this
manual have been certied for use with RM410 and RM2510.
The table below displays the components and their part no.
* Replace “XXX” with the color code numbers. For color codes,
contact your supplier. For further information, contact your dealer or
distributor.
The ventilation kits must be installed and used without modi-
cation! An opening toward the outside at oor level in the
refrigerator compartment has be provided for ventilation of
heavier-than-air fuel gases. The lower vent of the recommended
kits is provided with proper size openings. The ow of combus-
tion and ventilating air must not be obstructed.
The lower side vent is tted with a panel, which provides an
adequate access opening for ready serviceability of the burner
and control manifold of the refrigerator. This should be cen-
tered on the back of the refrigerator.
NOTE!
While washing the RV - do not spray any water
through the refrigerator vents.
Certied vent system kits
Kit no. Components Part no.
3A Roof Base
Roof Cover
Lower Side Vent
3103633.XXX*
3103634.XXX*
3109350.XXX*
Comments to this Manuals