Just above the burner assembly, located in the
generator section of the cooling unit, are the
12 volt DC and 120 volt AC heating elements
that provide the heat to the cooling unit on
those modes.
(14)
By removing the two screws on the left side of
the base assembly and one screw in the burner
area, rotate the clamping plate clockwise to
remove it.
(15)
The mounting plate assembly can then be
moved backward to gain access to the re-
maining parts in the control system.
(16)
From this view we can see the Printed Circuit
Board which controls the automatic heat
selection functions of the refrigerator and the
12 volt DC relay which energizes the 12 volt
DC heating element when the automatic
selection calls for 12 volt operation. To the
right of the DC relay is the igniter reigniter
module.