As in all of our troubleshooting steps, the
printed circuit board is the last component to
check for a failure. Insure that all of the
connections on the board are clean and are
inserted in their proper locations before
attempting to determine if the
printed circuit
board is at fault.
(108)
Many times when a circuit board failure is
noticed it will be visible as a burned section on
the board. Determine the cause of the board
failure by referring to SERVICE BULLETIN
R56-7A
(pages A-
1
l-3 to A- 11-5) and correct
the external problem before replacing the
circuit board. FAILURE TO DO SO COULD
RESULT IN REPEATED BOARD
PROBLEMS.
(109)
NO 120 VOLT AC OPERATION. To begin
our diagnosis of the 120 volt mode, determine
if the house battery and its associated wiring
is adequate to operate the electronic circuitry
properly, as we discussed in the “no operation”
section of our program.
NO 120 V.A.C. OPERATION
Also, determine if the AC voltage to the
refrigerator is within 10 percent of the rated
stamped voltage on the heating element.
Correct any wiring or voltage problems as
needed to provide an adequate power supply to
the refrigerator.
A-6-37