When beginning to diagnose the heating
element circuit, keep in mind that an
approximate DC voltage of 13.3 to the
terminal block is required to engage to 12 volt
DC heating element. Any voltage lower than
13.3 will prevent DC operation and the
refrigerator will operate on the LP gas mode.
(122)
After verifying that the 12 volt battery circuit
is wired properly and that the proper gauge
wire size has been utilized. Check the DC
voltage at the terminal block to insure that at
least 13.3 volts is available to energize the 12
volt heating element.
(123)
If proper voltage is available at the terminal
block and the refrigerator is still not
operational on 12 volts, the DC relay needs to
be diagnosed.
(124)
Gain access to the relay and make sure the
ignition switch is turned to the off position
and voltage is not present at the ignition lock
terminal. DC voltage should be present
between terminals 85 and 30 on the relay. If
voltage is not present, recheck all 12 volt
connections.
Pay close attention to the
connections on the positive terminal, as this is
where the 30 terminal attaches.
A-6-41
48