Refer to the RM3801 switch diagnosis
troubleshooting
section of
the
A.E.S.
Diagnostic Manual for a detailed explanation
on how to troubleshoot these switches. (See
pages A-8-l to A-8-5)
(104)
The next component to diagnose is the
solenoid valve’s internal winding. The A.E.S.
control system uses the solenoid winding to
provide a ground circuit to the printed circuit
board for all modes of operation. If the
solenoid winding is defective, the refrigerator
will not operate on any heat source.
(105)
To check the solenoid winding, remove all
power sources from the refrigerator, AC and
DC and unplug the connector at the solenoid
by pulling firmly outward.
Measure the resistance value across the upper
and lower terminals on the valve assembly.
The proper valve should be 20 ohms with
tolerance range of 10 percent. Values outside
the tolerance range or no ohms reading would
indicate a defective solenoid valve winding.
A-6-36