To diagnose a gas operational problem be sure
the refrigerator is in the A.E.S. mode.
(133)
The first diagnostic step is to be sure there are
proper DC volts at the terminal block, in
accordance with the previous explanation on
the DC power source. (See pages A-6-33
through A-6-34, paragraphs 92-96)
(134)
Next, check to be sure the 120 volt power cord
to the refrigerator is unplugged from the
receptacle. Then check for voltage at the
terminal block between the ignition lock
terminal and the negative terminal.
If
any
voltage is present you will not be able to have
gas operation. These must be corrected before
any further checks can be done.
(135)
Now that we have proper DC voltage, no 120
volt and the ignition lock is not energized, we
can start to diagnose the gas system. Be sure
the manual gas shut-off valve is in the off
position. Remove the twelve (12) millimeter
gas test port plug and install a
l/8
NPT fitting
in its place.
A-6-44
51