Remove the two thermostat leads and place
them together using electrical tape. This will
by-pass the thermostat from the electrical
circuit. If the refrigerator begins operating
when the leads are by-passed, the thermostat
is defective and must be replaced. Be careful
not to touch any surrounding metal parts with
the thermostat lead ends when performing this
procedure, as this will needlessly blow the 3
amp. protection fuse.
(101)
The main switch contains many different
functions in the A.E.S. refrigerators, which
includes controlling the heat sources. In this
section we will discuss the troubleshooting
procedures for the entire switch functions,,
including the mode switch lamps as well as the
function lamps. Before gaining access to the
switch, visually inspect the switch cable for
any cuts or shorts. Check to see that the plug
connector is properly inserted into the
printed
circuit board connection.
(102)
Next, disconnect the positive and negative
battery leads from the terminal block. All of
our diagnosis on the switch will be made with
continuity or ohm’s resistance. Failure to
disconnect the DC power supply during
diagnosis could result in switch failure if it
inadvertently touches metal.