AES Refrigerator CONTINUITY READINGS FOR SWITCH CARD
&
HARNESS continued
B. With the gas function switch NOT depressed, no continuity should be indicated between the
violet terminal on the 10 pin connector to the orange terminal on the 10 pin connector.
5. GAS FUNCTION LAMP
Measure resistance between the brown terminal on the
10
pin connector to white terminal on
the 10 pin connector. The proper resistance is approximately 65,000 OHM S.
6. GAS FLAME WARNING LAMP
Measure resistance between the brown terminal on the 10 pin connector to the black terminal
on the 10 pin connector. The proper resistance is approximately 2 1,000 OHMS.
In normal operation the gas flame warning lamp will illuminate if the refrigerator fails toNOTE:
light after approximately 3 minutes. This lamp, however, will illuminate within
approximately 10 seconds if the refrigerator fails to spark in the gas mode.
A-8-5