Dometic RM 2801 Service Manual Page 46

  • Download
  • Add to my manuals
  • Print
  • Page
    / 94
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 45
(115)
Do not diagnose the heating element by
checking only for continuity. A continuity
DO NOT DIAGNOSE THE
check does not properly check the integrity of
the element. If a zero ohms reading is
indicated, an internal short is present in the
heating element. Heater replacement would
then be necessary.
HEATING ELEMENT BY
CHECKING
ONLY FOR CONTINUITY
(116)
At this time, also inspect the printed circuit
board for burned marks or damaged board
components using SERVICE BULLETIN
R56-
7A
(pages A-l l-3 to A-l l-5). Whenever
diagnosing
120 volt
problems
alwavs
remember to verify the heating element’s ohms
resistance. A shorted 120 volt heating element
can cause permanent printed circuit hoard
failure. (See pages A-l l-3 to A- 1 l-5)
(117)
After diagnosing the heating element, insure
that all of the connections on the module
board are inserted correctly and that there are
no damaged leads that could cause circuit
board failure.
A-6-39
46
Manual Compliments of
Northwest RV Supply
Printed From
http://www.nwrvsupply.com
Page view 45