Measure resistance across the leads as outlined
earlier in our program for the 120 volt heating
element. The reading, however, will be
different from the AC heating element. For
the models RM3601 and RM3801 the ohms
resistance should be
.67,
with a tolerance range
of 10 percent. If there is no ohms reading or a
reading outside the 10 percent tolerance range,
the heater is defective and must be replaced.
Please note that it will take a very precise ohm
meter to accurately read this measurement.
(130)
A malfunctioning switch assembly may also
affect the DC mode. As outlined in previous
diagnostic steps in our program, diagnose the
switch for proper operation. In our final check
of the 12 volt cooling system, check all wiring
harnesses and leads for shorts or opens. If
necessary use an ohm meter, end to end, on
the suspect leads.
(131)
NO LP GAS OPERATION
NO LP GAS OPERATION