It must be remembered that a DC wire hook-
up to the terminal block is required for any
A.E.S. refrigerator to operate on 120 volts AC,
12 volts DC or LP gas.
(10)
From the rear of our example we can see the
shut-off valve and knob where the main LP
gas supply is connected to the refrigerator, 12
volt DC terminal block where the 12 volt
power source comes into the refrigerator to
operate the system and the LP gas solenoid
valve which includes the 12 millimeter test
plug where the LP gas pressure can be
checked.
(11)
The solenoid valve replaces the user operated
flame failure safety device that is found on the
manually controlled refrigerator models.
(12)
Finally, to the right of the solenoid valve is
the orifice burner assembly which generates
the heat required on the LP gas mode to
operate the absorption cooling unit.
A-6-4