The customer can manually select the controls
to operate on AC and LP gas only; again with
AC having priority over the LP gas mode or
the customer may select LP gas only.
When the main switch is turned on the
electronic control system will always select the
fully automatic mode. At this time the A.E.S.
pushbutton switch will illuminate green
indicating the system has selected the fully
automatic mode. As with the earlier A.E.S.
models the refrigerator will select between 120
volts AC, 12 volts DC or LP gas.
If the customer desires the selection to be
made only between 120 volts and LP gas, the
customer simply
pushes the
AC gas
pushbutton. As soon as the button is energized
the A.E.S. lamp will shut off and the AC gas
pushbutton will illuminate green. This
indicates the refrigerator will select only
between 120 volts and LP gas, so that even
while the customer is traveling, and 12 volts
DC is available at the ignition lock terminal,
the unit will not operate the 12 volt heating
element. Instead, the system will select the LP
gas mode while traveling.