(139)
You should hear a sharp click from the
solenoid and now obtain a gas pressure
reading. If these results are not realized the
solenoid is defective and must be replaced.
(140)
If these results are correct you must next
check the wires that connect to the solenoid
voltage. The results should be close to the
voltage coming to the appliance.
(141)
We will now check the igniter-reigniter
assembly. First turn the unit on and check for
voltage between the positive and ground
terminals on the igniter. If you obtain a DC
voltage reading, the igniter is receiving power.
(142)
If you do not obtain a reading, move the meter
probe from the ground terminal of the igniter
to the negative terminal on the terminal block.
If you now have a reading on the meter and
you did not at the igniter, you have a problem
in the ground circuit. If you obtained a
reading on both the tests, the igniter is
receiving power.