AES Refrigerator CONTINUITY READINGS FOR SWITCH CARD
&
HARNESS continued
IO. DELAY MODE LAMP AND SWITCH
A. With the mode switch manually depressed, resistance should be indicated between the brown
terminal on the
10
pin connector to the yellow terminal on the 7 pin connector. The proper
resistance is approximately 2 1,000 OHMS.
B. With the mode switch NOT depressed, no resistance should be indicated between the brown
terminal on the 10 pin connector to the yellow terminal on the 7 pin connector.
Il. GAS MODEL LAMP AND SWITCH
A. With the mode switch manually depressed, resistance should be indicated between the brown
terminal on the 10 pin connector to the green terminal on the 7 pin connector. The proper
resistance is approximately 21,000 OHMS.
B. With the mode switch NOT depressed, no resistance should be indicated between the brown
terminal on the 10 pin connector to the green terminal on the 7 pin connector.
12. GAS FLAME WARNING LAMP
Measure resistance between the brown terminal on the 10 pin connector to black terminal on the
10 pin connector. The proper resistance is approximately 21,000 OHM
S.
NOTE:
In normal operation, the gas flame warning lamp will illuminate if the refrigerator fails to
light after approximately 3 minutes. This lamp, however, will illuminate within
approximately 10 seconds if the refrigerator fails to spark in the gas mode.