Bulletin
#R60/7A
continued
AES
PRE-DELIVERY CHECK FOR
MODELS RM3601 AND RM3801
1. The AES automatically selects the best energy source for the situation, either 120 volts, 12
volts or LP gas.
2. This unit will also let you select the energy source you want.
3. Pictured below is the AES control panel that is found on this generation of AES refrigerators.
A
B
C
D
E F G H J
K
A.
Push button, green indicator
-
Full AES operation.
B.
Push button, green indicator - Limited AES operation:
C.
D.
E.
F.
G.
H.
I.
J.
AES CONTROL PANEL ON REFRIGERATOR
120 volts or LP gas (priority to 120 volts).
Push bottom, green indicator - LP gas operation only.
Main switch - Push right, to turn unit ON. Push left to turn unit OFF.
Yellow indicator - 120 volt operation mode.
Yellow indicator - 12 volt operation mode.
Yellow indicator
-
LP gas delay mode.
Yellow indicator
-
LP gas operation.
Question mark
-
push button. When pushed this button will indicate which mode is in
operation,
E-F-G or H.
Flame Failure indicator - Indicates unit tried to light on LP gas and failed.
OPERATIONAL TEST
6.
Make sure you have a good 120 volt supply
available.
7.
You must also have a good 12 volt supply.
Be sure all LP gas valves have been turned
on, those at LP tanks and at rear of refriger-
ator.
Turn ON/OFF switch
“D”
to the ON position.
8.
D
Connect 120 volt supply to unit.
When switch
“D”
is set to ON, the AES
button will light up (green), indicating that
the control system is in the automatic mode.
In this mode 120 volts A/C has priority.
Push the question mark button “J”.
Now
yellow indicator
“E”
(A/C) should light up.
OFF ON
J
E
A-ll-13