(64)
Another significant change in the third
generation A.E.S. system is how the 12 volt
heating element mode operates. As with the
first and second generation series, the 12 volt
heating element circuit is energized by the
ignition lock terminal. This terminal receives
its DC voltage from a wire that runs from the
run side of the vehicle’s ignition switch to the
refrigerator’s ignition lock terminal. This
allows the 12 volt heating element to be
energized only when the RV is traveling down
the road.
(65)
TAG LINE ENERGIZED
When the ignition lock terminal is energized
by the ignition key, the printed circuit board
must see at least 13.3 volts DC for a period of
40 seconds before the system will activate the
12 volt DC heating element.
VOLTAGE
---)
13.3 V.D.C.
(FOR 40 SEC. MIN.)
12V ELEMENT
ENERGIZES
(66)
If 13.3 volts is not achieved in this time frame,
the electronics will light the LP gas burner and
the refrigerator will operate on the LP gas
mode.
LOWER THAN 13.3 V.D.C. =
L.P. GAS
OPERATION