Page view 27
(70)
TAG LINE ENERGIZED
Secondly, suppose a customer has a properly
wired RM3801 in a motor home that is
equipped with a fully functional alternator.
After the ignition key is turned on, the printed
circuit board determines that at least 13.3 volts
is available at the terminal block, so the 12
volt heating element engages.
VOLTAGE
---)
13.3 V.D.C.
(FOR 40 SEC. MIN.)
12V ELEMENT
ENERGIZES
(71)
When the customer leaves on the trip it is a
hot, muggy night so the vehicle’s headlamps as
well as the dash air conditioning system is
turned on. After a few minutes of driving it
begins to rain, so the windshield wipers are
also turned on. With all of these components
operating in the coach, the alternator has
difficulty keeping up with the demand of the
total coach load and the house battery begins
to drain. As soon as the printed circuit board
sees that the battery voltage going to the
refrigerator has dropped to approximately
volts, the electronic circuitry will shut off the
12 volt DC heating element to protect the
house battery, At this time, an approximate 25
minute delay cycle will be in progress.
LOWER THAN 11 V.D.C. =
HEATING
ELEMENT
OFF
SAFETY DELAY
(72)
If the battery voltage remains low after the
delay cycle, the automatic controls will light
the refrigerator on the LP gas mode and stay
on the gas mode until the printed circuit board
sees approximately 13.3 volts DC to the
terminal block.
LOWER THAN 13.3 V.D.C.
FOR 25 MIN. OR MORE q
L.P. GAS
OPERATION